    标准数据表  

[用户手册](/products/liquid-cooling-systems/nextreme-recirculating-chillers/NRC400-T0-00-PC2/user-manual)

MFG Part Number 385901-002

# NRC400-T0-00-PC2

## Nextreme™ NRC400 Performance Chiller

The Nextreme NRC400 is a next generation benchtop recirculating chiller using solid-state thermoelectric technology for precise temperature control of analytical and industrial equipment. It offers high heat pumping capacity for its size, improved temperature stability and lower noise operation than previous models. Utilizing custom thermoelectric coolers with premium thermoelectric materials, it delivers a higher coefficient of performance (COP). The NRC400 is a semi-closed system with a large reservoir tank requiring less refilling. It is equipped with a high-quality pump offering high MTBF with low pulsation to accommodate highly sensitive imaging and test instruments. This model comes with an option to increase chiller performance using Boost Mode. With the Boost Mode ON, the fans run at a higher speed which increases the unit's performance to the maximum cooling capacity. Users can easily control temperature setpoints and alarm settings via the high-res LCD touchscreen display. Custom configurations are available, however, MOQ applies.

![Product image](/thermal-wizard/images/lcs/NRC400/NRC400-large.png)

### 特点

- 性能可靠
- 环保
- 用户友好
- 特定应用配置

### 应用

- [工业激光器](/cn/applications/industrial-laser-cooling)
- [增材制造](/cn/applications/additive-manufacturing)
- [电子显微镜](/cn/applications/electron-microscopes)
- [半导体制造设备冷却](/cn/applications/semiconductor-fabrication-equipment-cooling)
- [实验室测试](/cn/thermal-technical-library/application-notes/chillers-simplify-the-lab)

![Isometric drawing](/thermal-wizard/images/lcs/NRC400/NRC400-isometric-drawing.png)

### 技术指标

**性能**

Maximum Cooling Capacity2

 348 W Boost Mode OFF, 400 W Boost Mode ON

Setpoint Range

 -5°C to 40°C

Temperature Stability

 ±0.05°C

**运行**

冷却液

Water or Water/Glycol

运行温度

15°C to 40°C

储存温度范围（不含冷却液）

0°C to 50°C

湿度范围

35% to 85%

储存湿度范围

5% to 95%, non-condensing

输入电压

100 - 230 VAC

频率

50/60 Hz

电流

 &lt; 4.85 A

最大正向压力

 0.88 巴

兼容性

 ANSI / UL / CSA / IEC EN 61010-1 Edition 3

**物理尺寸**

高度

400 mm

长度

413 mm

宽度

274 mm

重量

24 kg

冷却液容量

 1 Liters

耦合

Refer to the NRC400 user manual for guidance (page 22)

### Cord Options

All compliance testing and validation has been done with these specific cord models.

Power cord is not supplied with the unit and must be ordered separately.

MFG Part Number

Plug Type

Standard

Style

Cable  
Length

Conductor  
Cross-Section

Color

Connector

Order

387009619

Australia

AS 3112

straight

2.0 m

3 x 1.5 mm²

Black

C13

387009620

Europlug

CEE 7 / VII

straight

2.0 m

3 x 1.5 mm²

Black

C13

387009621

China

GB 2099

straight

2.0 m

3 x 1.5 mm²

Black

C13

387009622

Japan

JIS 8303

straight

2.0 m

3 x 2 mm²

Black

C13

387009623

United Kingdom

BS 1363

straight

2.0 m

3 x 1.5 mm²

Black

C13

387009624

United States

NEMA 5-15P

straight

2.0 m

3 x 2 mm²

Black

C13

### Liquid Interface

![](/thermal-wizard/images/lcs/NRC400/NRC400-rear-interface.png)

###  
Cooling Power Operating Points1

Select Graph

 Cooling Capacity  
(Boost Mode ON) Cooling Capacity  
(Boost Mode OFF) ΔT (Inlet-Outlet)  
(Boost Mode ON) ΔT (Inlet-Outlet)  
(Boost Mode OFF) Pump Curve (Pressure vs Flow)

 **100% Water (20°C Ambient Air)**  
 Cooling Power (Qc) = 348 Watts  
 Boost Mode (Qc) = 400 Watts  
 Fluid Setpoint = 20 °C  
 Fluid ΔT @ 1.0 L/min = 5.0 °C  
 Boost Mode Fluid ΔT @ 1.0 L/min = 6.0 °C  

 **100% Water (30°C Ambient Air)**  
 Cooling Power (Qc) = 205 Watts  
 Boost Mode (Qc) = 266 Watts  
 Fluid Setpoint = 20 °C  
 Fluid ΔT @ 1.0 L/min = 3.0 °C  
 Boost Mode Fluid ΔT @ 1.0 L/min = 3.8 °C  

 **70/30 Water-Glycol (20°C Ambient Air)**  
 Cooling Power (Qc) = 317 Watts  
 Boost Mode (Qc) = 388 Watts  
 Fluid Setpoint = 20 °C  
 Fluid ΔT @ 1.0 L/min = 4.8 °C  
 Boost Mode Fluid ΔT @ 1.0 L/min = 5.9 °C  

 **70/30 Water-Glycol (30°C Ambient Air)**  
 Cooling Power (Qc) = 200 Watts  
 Boost Mode (Qc) = 258 Watts  
 Fluid Setpoint = 20 °C  
 Fluid ΔT @ 1.0 L/min = 3.0 °C  
 Boost Mode ΔT = 3.9 °C  

### Notes

1. Performance curve deviation is within +/-5%
2. Maximum Cooling Capacity rated at 20°C Ambient Air and 20°C Fluid Temperature w/ Boost Mode On
3. Use water as coolant for control temperatures above 10°C
4. To prevent freezing, use coolant with up to 30% glycol below 10°C
5. For alternate coolants please contact Laird Thermal Systems

Tark 及其代理机构所提供的任何信息，无论是规格参数、数据表、产品目录还是其他信息，都被认为是（但不保证是）准确和可靠，仅供参考， 并不构成与Tark合同的任何部分。所有规格参数如有更改，恕不另行通知。对于因使用或依赖此信息而造成的损失或损害， Tark 不承担任何责任。所有 Tark 产品在销售时均受当时有效的 Tark 销售条款和条件（包括 Tark 有限保修）约束，如有需要，将根据要求提供副本。  

 © Copyright 2026 Tark Thermal Solutions, Inc. All rights reserved.  

 Nextreme™ is a trademark of Tark Thermal Solutions, Inc. All other marks are owned by their respective owners.

Revision: 06 Date: 11-06-2025

Print Date: 10-21-2026

**Original URL:** https://tark-solutions.com/cn/products/liquid-cooling-systems/nextreme-recirculating-chillers/NRC400-T0-00-PC2