# TCDU Cooling Pumps

TCDU Series Cooling Pumps leverage a hermetically sealed pump combined with a motor controller for precision cooling in water-based direct-to-chip applications. TCDU Series Cooling Pumps offer high efficiency, extended life, and quiet operation with the added advantage of precise speed controls to deliver **variable flow and energy savings** for next‑generation **data center enclosures and coolant distribution units.**

- **High-performance output** with low energy consumption
- **Cooling capabilities** for 100kW – 200kW densities
- **Flow Rate** deliverables for  10 – 60 GPM / 38 – 225 LPM
- **Pressure capabilities** up to 33 PSI / 2.25 BAR
- **Liquid-cooled PCB & Motor**\*\*\* – No need for auxiliary fans
- **Quality material** selection to ensure longevity and no leaching
- **Compact footprint** to minimize space claim
- **Wet motor design** with 48V Brushless DC Motor
- **Low decibel** operation
- **Cavitation prevention** for increased longevity and efficiency
- **Connectivity** – Adjustable motor speed, temperature sensors, and current feedback

### [**Contact Us**](https://tark-solutions.com/contact-us?utm_source=TCDU_web&utm_medium=contact_button)

![data center CDU centrifugal pump](/sites/default/files/styles/high_xs/public/fields/media.image.field_media_image/2026-01/TCDU%20PCB%20with%20Cover%20Small_2.png.webp?itok=lOGdg11s)

### **The TCDU Series Advantage**

- Increased durability via optimized flow path and minimized wetted material wear
- Low energy consumption and power draw
- Precision motor controls that maximize cooling performance via liquid-cooled PCB and motor, Patent Pending\*\*\*
- Low maintenance design w/ easy service accessibility
- Adjustable speed for variable operation conditions
- Preventative maintenance communication
- Cavitation prevention measures
- Reduced footprint, minimizing space claim with rack (4u)

### [**Download FLOW COMPARISON CHART**](/sites/default/files/fields/media.file.field_media_file/2026-02/TCDU_pump_comparison_chart.pdf)

### [**Download  TCDU 150 DATASHEET PDF**](/sites/default/files/fields/media.file.field_media_file/2026-06/TCDU150_Cooling_Pump.pdf)

### TCDU Applications

![](/sites/default/files/fields/media.image.field_media_image/2025-04/data_center_icon_0.png)

- Coolant Distribution Units

![](/sites/default/files/inline-images/immersion_cooling_icon.png)

- Immersion Cooling

![](/sites/default/files/inline-images/energy_savings_icon_0.png)

- Energy Conscious Data Centers

### **TCDU Series Cooling Pump Specifications**

|  | **TCDU75** | **TCDU100** | **TCDU150** | **TCDU200** |
|---|---|---|---|---|
| Input Voltage | 48VDC | COMING IN 2026 |
| Power | 600W | 800W | 1250W |
| Variable Speed (RPM) | 500 - 5000 |
| Flow Rate Range (GPM/LPM) | 5-30 / 20-110 | 10-40 / 40-150 | 10-60 / 38-225 |
| Pressure Range (PSI/BAR) | 7-25 / .5-1.7 | 15-33 / 1-2.2 | 26-33 / 1.8-2.25 |
| Inlet/Discharge\* | 1 ½” SanitaryClamp | 1 ½” SanitaryClamp | 2” Sanitary   Clamp |
| Reliability | Minimum 80,000 hours / 10 years |
| Temperature Range (°C) | 10 - 80 | 40 |
| Communication\* | ModBus RS485 |

**\*Customization available as well as multiple outlet configurations upon request**

### **Wetted Material**

| **SHAFT** | **MAGNETS** | **ROTOR** | **HOUSING** | **BEARINGS** | **O-RINGS** | **IMPELLER** | **WEAR RING** | **TUBING** |
|---|---|---|---|---|---|---|---|---|
| 304SS | Neo w/ Nickel Plating | Silicon Steel | Aluminum or SS | SS or Hybrid Ceramic | EPDM/Silicon | 304 SS | Zinc Free Brass | PTFE |

### **TCDU150**

| ![](/sites/default/files/inline-images/TCDU-dimensiosn-front.png) | ![](/sites/default/files/inline-images/TCDU-dimensiosn-side.png) | ![](/sites/default/files/inline-images/TCDU-drawing.png) |
|---|---|---|

**Original URL:** https://tark-solutions.com/products/pumps/tcdu_series_cooling_pumps