WL5000
WL Series Liquid Cooling System
Note: This product has reached end of production. Please use the recommended replacement.Please click the [Remaining Inventory] button to see inventory available.
The recommended replacement is:
MFG Part Number: 387009381.02
Description: LA5000
The WL5000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is re-circulated using a high-pressure pump to assure maximum flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient environment using brand name fan. Manual adjustments can be made to control flow switch. Customized features are available, however, MOQ applies.

Features
- Cooling to ambient
- High heat pumping capacity
- Compact form factor
- Long life operation

技术指标
Fluid Operating Points
Select Graph
Cooling Power (Qc) = Watts
Thermal Conductance = W/°C
ΔT (Ambient-Coolant)* = °C
ΔT (Outlet-Inlet)** @ 6.0 L/min = °C
Cooling Power (Qc) = Watts
Thermal Conductance = W/°C
ΔT (Ambient-Coolant)* = °C
ΔT (Outlet-Inlet)** @ 6.0 L/min = °C
Cooling Power (Qc) = Watts
Thermal Conductance = W/°C
ΔT (Ambient-Coolant)* = °C
ΔT (Outlet-Inlet)** @ 6.0 L/min = °C
Cooling Power (Qc) = Watts
Thermal Conductance = W/°C
ΔT (Ambient-Coolant)* = °C
ΔT (Outlet-Inlet)** @ 6.0 L/min = °C
* ΔT (Ambient-Coolant) is the temperature difference between the ambient temperature and the coolant temperature that is at the outlet of the heat exchanger during steady-state operation. This temperature difference would initially be 0 and increase to the steady state value under load. This would also be the temperature at the inlet to the application.
** ΔT (Outlet-Inlet) is the temperature difference between the inlet temperature and the outlet temperature of the application at the nominal coolant flow. More flow (application pressure drop less than nominal) would necessarily mean a smaller ΔT.
Notes
- Check coolant level regularly. For optimal cooling performance, coolant level should always be above radiator fins.
- Hose selection should be of material and thickness to support pressure resistance and coolant type.
- Manual adjustments can be made to control pressure and flow rate.
- Check pump filter and dust on heat exchanger periodically for cleaning.
Tark 及其代理机构所提供的任何信息,无论是规格参数、数据表、产品目录还是其他信息,都被认为是(但不保证是)准确和可靠,仅供参考,
并不构成与Tark合同的任何部分。所有规格参数如有更改,恕不另行通知。对于因使用或依赖此信息而造成的损失或损害,
Tark 不承担任何责任。所有 Tark 产品在销售时均受当时有效的 Tark 销售条款和条件(包括 Tark 有限保修)约束,如有需要,将根据要求提供副本。
© Copyright 2019-2025 Tark Thermal Solutions, Inc. All rights reserved. Tark™, the Tark Logo, and Tark Thermal Solutions™ are trademarks or registered
trademarks of Tark Limited or its subsidiaries.
Revision: 00 Date: 06-01-2022
Print Date: 05-07-2025