Thermoelectric Cooler Assemblies for Reagent Storage

Maintaining a precise temperature below ambient, and monitoring this temperature carefully, are critical to extending the shelf life of reagents used in chemical and biological processes. Thermoelectric cooler assemblies provide a more efficient, reliable and cost-effective thermal control method compared to other thermal management technologies. 

 

Downloads

Presentation

SLA-400-24-02-00-00

The SLA-400-24-02 Liquid-to-Air thermoelectric cooler assembly is a high performance thermoelectric based liquid cooler. It is designed to temperature control small chambers used in medical diagnostics, lasers, imaging systems or sample storage compartments in analytical instrumentation. This unique, patented design offers a high performance hot side heat dissipation mechanism that convects heat more efficiently than conventional heat exchanger technologies.


Qc Max:


ISO 9001:2015 Durham & Gothenburg

IS0 9001:2015 certificate for multiple sites.

Page 1: Durham, US
Page 2: Gothenburg, Sweden 

Downloads

Certifications approvals

Additive Manufacturing

UltraTEC™ UTX Thermoelectric Coolers

For laser systems with a smaller footprint, thermoelectric coolers can be mounted directly onto the exterior of the laser. The UltraTEC™ UTX Series from Tark Thermal Solutions can cool well below ambient temperatures and dissipate heat away from sensitive components of 3D printers.

Learn more about the UltraTEC UTX Series

Quality & Environmental, Health & Safety Policy

Our quality mission is to build up and maintain high quality standards and a zero-defect culture in order to exceed customer satisfaction and provide reliable products for demanding applications across medical, analytical, industrial, transportation and telecommunications markets. This is our company quality policy. 

Downloads

Certifications approvals

MS5-257-10-15-00-W8

The MS5-257-10-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 2 Watts when ΔT = 0 and a maximum ΔT of 129 °C at Qc = 0.


Qc Max:


MS4-129-10-15-22-W8

The MS4-129-10-15-22-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 1.8 Watts when ΔT = 0 and a maximum ΔT of 120 °C at Qc = 0.


Qc Max:


MS4-129-10-15-00-W8

The MS4-129-10-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 1.8 Watts when ΔT = 0 and a maximum ΔT of 120 °C at Qc = 0.


Qc Max:


MS4-115-14-15-00-W8

The MS4-115-14-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 2.8 Watts when ΔT = 0 and a maximum ΔT of 124 °C at Qc = 0.


Qc Max: